Split structure, freezer unit and box can be placed separately.
Hole in the top of the box for easy lifting of the motor.
Soft silicone plug seal to avoid frosting when doing low temperature.
The central shaft adopts a special sealing device to avoid frost when doing low temperature.
Sizes of Drive In test chamber | ||||
Model
|
Volume (m³)
|
Temperature Range
(°C) |
Internal Dimension (mm) D*W*H
|
External Dimension (mm) D*W*H
|
LRHS-46MB-LJ
|
46
|
A: -20~150°C
B: -40~150℃ C: -60~150°C D: -70~150°C E: or customized |
5500*3000*2800
|
6250*3200*3300
|
Note: In the Model, the number means volume of test chamber's working room, and ABCD means the temperature range. For example, model LRHS-46MB-LJ means the volume of this test chamber is 46m³ and its temperature range is -40°C~+150°C. LRHS-46MC-LJ means the volume is 46m³ and the temeprature range is -60°C~+150°C |
||||
Basic Specification | ||||
Performance
|
Temperature Range | - 40℃~60℃ or customized | ||
Temperature Fluctuation | ±1.0°C | |||
Temperature Uniformity | ±2.0°C | |||
Humidity Range | 20%~80%RH | |||
Ramp Rate | 25℃~60℃≤2H for heating (non-linear, based on on-load) 25℃~-40℃≤2.5H for cooling (non-linear, based on on-load) Note: can be customized as per requirement |
|||
Material
|
External Casing | Cold-rolled A3 (Q235) steel plates with plastics painted. | ||
Interior Working Room | Stainless Steel Plates SUS304 with miror surface | |||
Heat Isolation | Polyurethane foams and fine glass fibres | |||
Structure of floor | Non-slip stainless steel, thickness ≥ 3mm, Heavy-duty flooring to support vehicles(1200kg ) | |||
Heating & Cooling System
|
Heater | Steipped Nickel-chromium Wire Heater | ||
Air Blower | Anti-temperature stainless fan blades with low noise | |||
Compressor | Hermetically-sealed Techmesh® or semi-sealed Bitzer® or GEA® or equivalent compressors | |||
Cooling Method | Single or dual cooling (Air-cooled or Water-cooled) | |||
Control System
|
Controller | 7" Programmable colorful touch-screen display LCD English Display Microcomputer integrated controller |
||
Functions | Data Record (Max 600 days x 24hrs), History Curve, USB data download & upload, Remote controlling through PC, Automatic protection alarms, etc. | |||
Temperature Sensor | Platinum Resistance.PT100Ω | |||
Humidity Sensor | Imported electronic humidity sensor | |||
Test load
|
Max power of the engine | 300KW | ||
Max inspiratory capacity of the vehicle | 720m3/h | |||
Max displacement of the vehicle | 3200m3/h | |||
Max heat of the vehicle | 300KW | |||
Exhaust pipe outlet maximum temperature | 350℃ | |||
Safety Protection | Power leakage protection/Compressor over-heat, over-load or over-current protection/Dry burning protection. | |||
Voltage | 380V/440V±10%, 50Hz/60Hz or as per requirement | |||
Ambient Enviromental for application | 5°C~+30°C ≤ 85%R.H | |||
Test Standards (not limited to) |
Get Price
ysl@bjyashilin.com 010-68174779Copyright © Beijing Yashilin Test Equipment Co., LTD 备案号:京ICP备08004694号