Split structure, freezer unit and box can be placed separately.
Hole in the top of the box for easy lifting of the motor.
Soft silicone plug seal to avoid frosting when doing low temperature.
The central shaft adopts a special sealing device to avoid frost when doing low temperature.
Sizes of Dust Test Chamber | ||||
Model
|
Volume (L)
|
Rated Power
|
Internal Dimension (mm) D*W*H
|
External Dimension (mm) D*W*H
|
LRHS-512-PS
|
512
|
2.5kw
|
800*800*800
|
1300*1050*1750
|
LRHS-800-PS
|
800
|
2.5kw
|
800*1000*1000
|
1300*1250*1950
|
LRHS-1000-PS
|
1000
|
2.5kw
|
1000*1000*1000
|
1600*1250*1980
|
LRHS-1500-PS
|
1500
|
2.5kw
|
1000*1500*1000
|
1600*1750*1980
|
Basic Specification | ||||
Performance
|
Air speed | Not Exceed 2m/s Lowing | ||
Time setting Range | 1~999H adjustable | |||
Sand and dust concentration | 2~4kg/m3 | |||
Test Dust | Dry Talcum powder,Silicate cement,smoke ash,etc. | |||
Vacuum pump flow control | 60~600L/H | |||
Dust method | continous.period blowing dust time setting is optional | |||
Structure
|
External Casing | Cold-rolled A3 (Q235) steel plates with plastics painted. | ||
Interior Working Room | Stainless Steel Plates SUS304 with miror surface | |||
Heat Isolation | Polyurethane foams and fine glass fibres | |||
Viewing Window | Toughened glass with conductive films for heating to defrost(395×395mm) | |||
Door | Manually operated sliding door with unlock button | |||
Control System
|
Controller | Programmable Touch-screen controller “weinview” with data logging and download function | ||
Heating System | Steipped Nickel-chromium Wire Heater | |||
Dust dehumidification | Heating and dehumidification | |||
Vibration time | 1S-99H adjustable | |||
Blowing time | 1S-99H adjustable | |||
Cycle time | Arbitrarily set the blowing time | |||
Dust heat | Use stainless steel Mica Heating coil constant control to prevent dust adhesion | |||
Standard Configuration | Test Chamber x 1,Dust scraperx 1, talcum powder x 100g , EMO x 1, Tri-color Indicator x 1, etc. | |||
Safety Protection | Power leakage protection, over-load or over-current protection/Fan motor overheating/Dry burning protection. | |||
Voltage | AC220V/380V/440V±10%, 50Hz/60Hz or as per requirement | |||
Ambient Enviromental for application | 5°C~+30°C ≤ 85%R.H | |||
Test Standards (not limited to) | IEC 60529 IP5X IP6X |