Language
| Sizes of Ultra Low Temperature Chamber | |||||
|
Model
|
Volume (L)
|
Temperature Range
(°C) |
Rated Power
|
Internal Dimension (mm) D*W*H
|
External Dimension (mm) D*W*H
|
|
LRHS-101-YD
|
101
|
﹣196℃~RT
|
2.5kw
|
450*450*500
|
1100*900*1350
|
|
LRHS-225-YD
|
225
|
3.0kw
|
500*600*750
|
1150*1100*1600
|
|
|
LRHS-504-YD
|
504
|
4.2kw
|
700*800*900
|
1350*1300*1750
|
|
|
LRHS-800-YD
|
800
|
6.2kw
|
800*1000*1000
|
1450*1500*1850
|
|
|
LRHS-1000-YD
|
1000
|
6.2kw
|
1000*1000*1000
|
1450*1500*1850
|
|
| Note: In the Model, the number means volume of test chamber's working room. For example, model LRHS-101-YD means the volume of this test chamber is 101L. LRHS-225-YD means the volume is 225L |
|||||
| Basic Specification | |||||
|
Performance
|
Temperature Range | -196℃~RT | |||
| Temperature Fluctuation | ≤1.0°C | ||||
| Temperature Uniformity | ±2.0°C | ||||
| Ramp Rate | ≥3°C/min Note: can be customized as per requirement |
||||
|
Material
|
External Casing | Cold-rolled A3 (Q235) steel plates with plastics painted. | |||
| Interior Working Room | Stainless Steel Plates SUS304 with miror surface | ||||
| Heat Isolation | Polyurethane foams and fine glass fibres | ||||
| Illumination Lamp | Philips® one in per standard test chamber. | ||||
| Casters | 4pcs, with PU covered for protection. Height adjustable and direction universal. | ||||
| Door | Manually operated sliding door with unlock button | ||||
|
Heating & Cooling System
|
Heater | Steipped Nickel-chromium Wire Heater | |||
| Air Blower | Anti-temperature stainless fan blades with low noise | ||||
| Compressor | Hermetically-sealed Techmesh® or semi-sealed Bitzer® or GEA® or equivalent compressors | ||||
| Cooling Method | Single or dual cooling (Air-cooled or Water-cooled) | ||||
| Refrigerant | Liquid Nitrogen | ||||
| Condenser | Plate-type heat exchanger | ||||
|
Control System
|
Controller | 7" Programmable colorful touch-screen display LCD English Display Microcomputer integrated controller |
|||
| Functions | Data Record (Max 600 days x 24hrs), History Curve, USB data download & upload, Remote controlling through PC, Automatic protection alarms, etc. | ||||
| Program | 1~1000 programs, 1~999 steps for per program, Max 99hrs 59mins for per program. 10 programs can be interlinked. | ||||
| Temperature Sensor | Platinum Resistance.PT100Ω | ||||
| Running Model | Constant/Fix-value Model and Programmable Model | ||||
| I/O Interface | Communicate port (RS485) to connect test chamber to a PC | ||||
| Standard Configuration | Test Chamber x 1, Specimen Holder Shelf x 2, φ100mm Cable Access Port x 1 with 1 soft plug, EMO x 1, Tri-color Indicator x 1, etc. | ||||
| Safety Protection | Power leakage protection/Compressor over-heat, over-load or over-current protection/Dry burning protection. | ||||
| Voltage | AC220V/380V/440V±10%, 50Hz/60Hz or as per requirement | ||||
| Ambient Enviromental for application | 5°C~+30°C ≤ 85%R.H | ||||
| Test Standards (not limited to) | IEC60068-2-1
IEC60068-2-2
IEC60068-2-78
IEC60068-2-30
|
||||

Get Price
ysl@bjyashilin.com 010-68174779Copyright © Beijing Yashilin Test Equipment Co., LTD 备案号:京ICP备08004694号
Website Map:Sitemap