Split structure, freezer unit and box can be placed separately.
Hole in the top of the box for easy lifting of the motor.
Soft silicone plug seal to avoid frosting when doing low temperature.
The central shaft adopts a special sealing device to avoid frost when doing low temperature.
Sizes of Rustproof Grease Humidity Test Chambers | |||||
Model
|
Volume (L)
|
Performance
|
Rated Power
|
Internal Dimension (mm) D*W*H
|
External Dimension (mm) D*W*H
|
LRHS-101-RFX
|
101
|
Temperature Range(°C)
Rt+5°C~65°C |
2.5kW
|
450*450*550
|
690*640*1270
|
LRHS-228-RFX
|
225
|
3.5kW
|
580*580*680
|
820*770*1400
|
|
LRHS-400-RFX
|
504
|
4.5kW
|
680*680*800
|
920*870*1520
|
|
Note: In the Model, the number means volume of test chamber's working room. For example, model LRHS-101-RFX means the volume of this test chamber is 101L |
|||||
Basic Specification | |||||
Performance
|
Temperature | Range: RT+5°C~65°C Fluctuation:±1°C |
|||
Ramp Rate | Ramp up rate and stable time ≤60min | ||||
Humidity Range | ≥95% R.H | ||||
Air Ventilation Volume | 0.5m³/h (0.1~1m3/H adjustable in the range) | ||||
Chamber Bottom Water Depth | 200mm | ||||
Test Sample Shelf Rotate Speed | 1~3r/min ±10% | ||||
Material
|
External Casing | Cold-rolled A3 (Q235) steel plates with plastics painted. | |||
Interior Working Room | Stainless Steel Plates SUS304 with miror surface | ||||
Heat Isolation | Polyurethane foams and fine glass fibres | ||||
Illumination Lamp | Philips® one in per standard test chamber. | ||||
Casters | 4pcs, with PU covered for protection. Height adjustable and direction universal. | ||||
Viewing Window | Multi-layer hollow toughened glass with conductive films for heating to defrost | ||||
Door | Manually operated sliding door with unlock button | ||||
Heating & Cooling System
|
Heater | Steipped Nickel-chromium Wire Heater | |||
Air Blower | Anti-temperature stainless fan blades with low noise | ||||
Control System
|
Controller | ST190 LCD English Display Microcomputer integrated controller |
|||
Temperature Sensor | Platinum Resistance.PT100Ω | ||||
Running Model | Constant/Fix-value Model and Programmable Model | ||||
I/O Interface | Communicate port (RS485) to connect test chamber to a PC | ||||
Standard Configuration | Test Chamber x 1, Specimen Holder Shelf x 2, φ100mm Cable Access Port x 1 with 1 soft plug, EMO x 1, Tri-color Indicator x 1, etc. | ||||
Safety Protection | Power leakage protection/Compressor over-heat, over-load or over-current protection/Dry burning protection. | ||||
Voltage | AC220V/380V/440V±10%, 50Hz/60Hz or as per requirement | ||||
Ambient Enviromental for application | 5°C~+30°C ≤ 85%R.H | ||||
Test Standards (not limited to) | JIS K2246-89
GB/T2361-92
|
Get Price
ysl@bjyashilin.com 010-68174779Copyright © Beijing Yashilin Test Equipment Co., LTD 备案号:京ICP备08004694号