Split structure, freezer unit and box can be placed separately.
Hole in the top of the box for easy lifting of the motor.
Soft silicone plug seal to avoid frosting when doing low temperature.
The central shaft adopts a special sealing device to avoid frost when doing low temperature.
Sizes of Temperature Humidity Altitude Chambers | |||||
Model
|
Volume (L)
|
Temperature Range(°C)
|
Humidity Range (R.H)
|
Internal Dimension (mm) D*W*H
|
External Dimension (mm) D*W*H
|
LRHS-101B-LF
|
101
|
A: -20~150°C
B: -40~150°C C: -60~150°C D: -70~150°C |
20%~98% R.H
or customized |
450*450*500
|
1500*1120*1930
|
LRHS-225B-LF
|
225
|
500*600*750
|
1550*1270*2160
|
||
LRHS-504B-LF
|
504
|
700*800*900
|
2000*1470*2290
|
||
LRHS-800B-LF
|
800
|
800*1000*1000
|
1900*1560*2550
|
||
LRHS-1000B-LF
|
1000
|
1000*1000*1000
|
1560*1550*2170
|
||
Note: In the Model, the number means volume of test chamber's working room, and ABCD means the temperature range. For example, model LRHS-101A-LF means the volume of this test chamber is 101L, and its temperature range is -20°C~+150°C. LRHS-225C-LF means the volume is 225L and the temeprature range is -60°C~+150°C |
|||||
Basic Specification | |||||
Performance
|
Temperature Range | A: -20~150°C, B: -40~150°C, C: -60~150°C, D: -70~150°C, E : or customized | |||
Temperature Fluctuation | ±0.5°C ( without load ) | ||||
Temperature Uniformity | ±2.0°C ( without load ) | ||||
Ramp Rate | ﹣25°C~100°C≤50min (100kPa, without load ) 25°C~-20℃ ≤40min ( 100kPa,without load ) |
||||
Pressure | Atmospheric pressure ~0.5kPa | ||||
Depressureization time | Atmospheric pressure ~0.5kPa≤45min | ||||
Humidity Range | 20%~98% R.H | ||||
Humidity Fluctuation | ±2% | ||||
Humidity Fluctuation | ﹢2% -3% R.H | ||||
Material
|
External Casing | Cold-rolled A3 (Q235) steel plates with plastics painted. | |||
Interior Working Room | Stainless Steel Plates SUS304 with miror surface | ||||
Heat Isolation | Polyurethane foams and fine glass fibres | ||||
Illumination Lamp | Philips® one in per standard test chamber. | ||||
Casters | 4pcs, with PU covered for protection. Height adjustable and direction universal. | ||||
Viewing Window | Multi-layer hollow toughened glass with conductive films for heating to defrost | ||||
Door | Manually operated sliding door with unlock button | ||||
Heating & Cooling System
|
Heater | Steipped Nickel-chromium Wire Heater | |||
Air Blower | Anti-temperature stainless fan blades with low noise | ||||
Compressor | Hermetically-sealed Techmesh® or semi-sealed Bitzer® or GEA® or equivalent compressors | ||||
Cooling Method | Single or dual cooling (Air-cooled or Water-cooled) | ||||
Refrigerant | R404A or/and R23 (eco-friendly) | ||||
Condenser | Plate-type heat exchanger | ||||
Control System
|
Controller | 7" Programmable colorful touch-screen display LCD English Display Microcomputer integrated controller |
|||
Functions | Data Record (Max 600 days x 24hrs), History Curve, USB data download & upload, Remote controlling through PC, Automatic protection alarms, etc. | ||||
Program | 1~1000 programs, 1~999 steps for per program, Max 99hrs 59mins for per program. 10 programs can be interlinked. | ||||
Temperature Sensor | Platinum Resistance.PT100Ω | ||||
Running Model | Constant/Fix-value Model and Programmable Model | ||||
I/O Interface | Communicate port (RS485) to connect test chamber to a PC | ||||
Standard Configuration | Test Chamber x 1, Specimen Holder Shelf x 2, φ100mm Cable Access Port x 1 with 1 soft plug, EMO x 1, Tri-color Indicator x 1, etc. | ||||
Safety Protection | Power leakage protection/Compressor over-heat, over-load or over-current protection/Dry burning protection. | ||||
Voltage | 380V/440V±10%, 50Hz/60Hz or as per requirement | ||||
Ambient Enviromental for application | 5°C~+30°C ≤ 85%R.H | ||||
Test Standards (not limited to) | IEC68-2-40
IEC68-2-41
GJB1 50.2A
|
Get Price