Language
| Sizes of High and Low Temperature Low Pressure Test Chamber | |||||
|
Model
|
Volume (L)
|
Temperature Range(°C)
|
Humidity Range (R.H)
|
Internal Dimension (mm) D*W*H
|
External Dimension (mm) D*W*H
|
|
LRHS-101B-LF
|
101
|
A: -20~150°C
B: -40~150°C C: -60~150°C D: -70~150°C |
20%~98% R.H
or customized |
450*450*500
|
1500*1120*1930
|
|
LRHS-225B-LF
|
225
|
500*600*750
|
1550*1270*2160
|
||
|
LRHS-504B-LF
|
504
|
700*800*900
|
2000*1470*2290
|
||
|
LRHS-800B-LF
|
800
|
800*1000*1000
|
1900*1560*2550
|
||
|
LRHS-1000B-LF
|
1000
|
1000*1000*1000
|
1560*1550*2170
|
||
| Note: In the Model, the number means volume of test chamber's working room, and ABCD means the temperature range. For example, model LRHS-101A-LF means the volume of this test chamber is 101L, and its temperature range is -20°C~+150°C. LRHS-225C-LF means the volume is 225L and the temeprature range is -60°C~+150°C |
|||||
| Basic Specification | |||||
|
Performance
|
Temperature Range | A: -20~150°C, B: -40~150°C, C: -60~150°C, D: -70~150°C, E : or customized | |||
| Temperature Fluctuation | ±0.5°C ( without load ) | ||||
| Temperature Uniformity | ±2.0°C ( without load ) | ||||
| Ramp Rate | ﹣25°C~100°C≤50min (100kPa, without load ) 25°C~-20℃ ≤40min ( 100kPa,without load ) |
||||
| Pressure | Atmospheric pressure ~0.5kPa | ||||
| Depressureization time | Atmospheric pressure ~0.5kPa≤45min | ||||
| Humidity Range | 20%~98% R.H | ||||
| Humidity Fluctuation | ±2% | ||||
| Humidity Fluctuation | ﹢2% -3% R.H | ||||
|
Material
|
External Casing | Cold-rolled A3 (Q235) steel plates with plastics painted. | |||
| Interior Working Room | Stainless Steel Plates SUS304 with miror surface | ||||
| Heat Isolation | Polyurethane foams and fine glass fibres | ||||
| Illumination Lamp | Philips® one in per standard test chamber. | ||||
| Casters | 4pcs, with PU covered for protection. Height adjustable and direction universal. | ||||
| Viewing Window | Multi-layer hollow toughened glass with conductive films for heating to defrost | ||||
| Door | Manually operated sliding door with unlock button | ||||
|
Heating & Cooling System
|
Heater | Steipped Nickel-chromium Wire Heater | |||
| Air Blower | Anti-temperature stainless fan blades with low noise | ||||
| Compressor | Hermetically-sealed Techmesh® or semi-sealed Bitzer® or GEA® or equivalent compressors | ||||
| Cooling Method | Single or dual cooling (Air-cooled or Water-cooled) | ||||
| Refrigerant | R404A or/and R23 (eco-friendly) | ||||
| Condenser | Plate-type heat exchanger | ||||
|
Control System
|
Controller | 7" Programmable colorful touch-screen display LCD English Display Microcomputer integrated controller |
|||
| Functions | Data Record (Max 600 days x 24hrs), History Curve, USB data download & upload, Remote controlling through PC, Automatic protection alarms, etc. | ||||
| Program | 1~1000 programs, 1~999 steps for per program, Max 99hrs 59mins for per program. 10 programs can be interlinked. | ||||
| Temperature Sensor | Platinum Resistance.PT100Ω | ||||
| Running Model | Constant/Fix-value Model and Programmable Model | ||||
| I/O Interface | Communicate port (RS485) to connect test chamber to a PC | ||||
| Standard Configuration | Test Chamber x 1, Specimen Holder Shelf x 2, φ100mm Cable Access Port x 1 with 1 soft plug, EMO x 1, Tri-color Indicator x 1, etc. | ||||
| Safety Protection | Power leakage protection/Compressor over-heat, over-load or over-current protection/Dry burning protection. | ||||
| Voltage | 380V/440V±10%, 50Hz/60Hz or as per requirement | ||||
| Ambient Enviromental for application | 5°C~+30°C ≤ 85%R.H | ||||
| Test Standards (not limited to) | IEC68-2-40
IEC68-2-41
GJB1 50.2A
|
||||

Get Price