Language
Model
|
Volume (L)
|
Temperature Range
(°C) |
Rated Power
|
Internal Dimension (mm) D*W*H
|
External Dimension (mm) D*W*H
|
LRHS-101-NO3
|
101
|
25°C ~ 65°C
|
4.0kw
|
450*450*500
|
1160*1000*1800
|
LRHS-225-NO3
|
225
|
5.5kw
|
500*600*750
|
1220*1150*2040
|
|
LRHS-504-NO3
|
504
|
7.0kw
|
700*800*900
|
1400*1350*2250
|
|
LRHS-800-NO3
|
800
|
9.0kw
|
800*1000*1000
|
1520*1540*2300
|
|
LRHS-1000-NO3
|
1000
|
11.5kw
|
1000*1000*1000
|
1720*1540*2300
|
|
Basic Specification | |||||
Performance
|
Temperature Range | 25°C ~ 65°C | |||
Temperature Fluctuation | ±0.5°C | ||||
Temperature Uniformity | ≤ 2.0°C | ||||
Temperature change speed | ± 2.0°C | ||||
Humidity Range | 40% ~ 95% | ||||
Humidity Deviation | +2 / -3% R.H | ||||
Ozone Concentration | 50~1000pphm or 50~300ppm | ||||
Ozone Concentration Deviation | ≤ ±10% | ||||
Air Flow Rate | 8~16mm/s | ||||
Rotate speed | 1~3r/min(adjustment) | ||||
Time Setting Range | 1~9999 h/m/s adjustable | ||||
Material
|
External Casing | Cold-rolled A3 (Q235) steel plates with plastics painted. | |||
Interior Working Room | Stainless Steel Plates SUS304 with miror surface | ||||
Heat Isolation | Polyurethane foams and fine glass fibres | ||||
Illumination Lamp | Philips® one in per standard test chamber. | ||||
Casters | 4pcs, with PU covered for protection. Height adjustable and direction universal. | ||||
Viewing Window | Multi-layer hollow toughened glass with conductive films for heating to defrost | ||||
Door | Manually operated sliding door with unlock button | ||||
Heating & Cooling System
|
Heater | Steipped Nickel-chromium Wire Heater | |||
Compressor | Hermetically-sealed Techmesh® or semi-sealed Bitzer® or GEA® or equivalent compressors | ||||
Cooling Method | Single or dual cooling (Air-cooled or Water-cooled) | ||||
Refrigerant | R404A or R23 (eco-friendly) | ||||
Condenser | Plate-type heat exchanger | ||||
Control System
|
Controller | 7" Programmable colorful touch-screen display LCD English Display Microcomputer integrated controller |
|||
Temperature Sensor | Platinum Resistance.PT100Ω | ||||
Standard Configuration | Test Chamber x 1, Specimen Holder platform x 1 | ||||
Safety Protection | Power leakage protection/Compressor over-heat, over-load or over-current protection/Dry burning protection. | ||||
Voltage | AC220V/380V/440V±10%, 50Hz/60Hz or as per requirement | ||||
Ambient Enviromental for application | 5°C~+30°C ≤ 85% R.H |