Language
| Sizes of IPX9 Waterproof Test Chamber | ||||
|
Model
|
Volume
|
Function
|
Internal Dimension
D*W*H (mm) |
External Dimension
D*W*H (mm) |
|
LRHS-IPX5/6/9K
|
14.5 m3
|
IPX5/X6/X9
|
2440 x 2440 x 2440
|
4850x1440x2000
|
| Basic Specification | ||||
|
Performance
|
IPX5 Function | φ6.3 mm water spray jet, distance 2.5~3.0 m Flow velocity: 12.5 L/min ±5% Test Time: 1 min/m2, 3 mins |
||
| IPX6 Function | φ12.5 mm water spray jet, distance 2.5~3.0 m Flow velocity: 100 L/min ±5% Test Time: 1 min/m2, 3 mins |
|||
| IP69K Function | Water temperature: 80 ± 5°C Spray Angle: 0°/30°/60°/90° Pressure: 1500 psi Test Time: at least 30s Rpm: 5 Distance from test item: 100~150 mm |
|||
|
Material
|
External Casing | Cold-rolled A3 (Q235) steel plates with plastics painted. | ||
| Interior Working Room | Stainless Steel Plates SUS304 with miror surface | |||
| Big Tube | Rugged PP | |||
| Illumination Lamp | Philips® x one inside chamber | |||
| Casters | With PU covered for protection. Fixable and moveable. | |||
| Viewing Window | Toughened glass with conductive films for heating to defrost | |||
| Door | Manually operated sliding door with unlock button | |||
|
Control System
|
Controller | Programmable Touch-screen controller with data logging and download function | ||
| Water Storage | Water tank for storing water for recycling use | |||
| Safety Protection | Power leakage protection, over-load or over-current protection/Dry burning protection. | |||
| Voltage | 380V/440V±10%, 50Hz/60Hz or as per requirement | |||
| Test Standards | IPX5, IPX6, IPX9K | |||
| Note | For further detailed specification, please contact Lenpure. | |||

Get Price
ysl@bjyashilin.com 010-68174779Copyright © Beijing Yashilin Test Equipment Co., LTD 备案号:京ICP备08004694号
Website Map:Sitemap