Split structure, freezer unit and box can be placed separately.
Hole in the top of the box for easy lifting of the motor.
Soft silicone plug seal to avoid frosting when doing low temperature.
The central shaft adopts a special sealing device to avoid frost when doing low temperature.
Main parameter | Studio size | 1000×1000×1000(D*W*H)mm | |||||
outline dimension | 3400×2000×2300(D*W*H)mm | ||||||
Impact temperature range | -55℃~85℃ | ||||||
Pre-cooling Temperature Range of the Cold Room | -75℃~0℃ | ||||||
Cooling time | 20℃~-75℃≤60min | ||||||
Recovery condition | High temperature exposure temperature:≤85℃,Exposure time:≤30min Low temperature exposure temperature:≤-55℃,Exposure time:≤30min |
||||||
Temperature recovery time | ≤5min | ||||||
Temperature fluctuation | ≤±0.5℃ | ||||||
Temperature deviation | ≤±2℃(no load) | ||||||
Temperature uniformity | ≤2℃(no load) | ||||||
Outer box material | High-quality A3 steel plate electrostatic spraying | ||||||
Inner box material | Imported high-grade stainless steel SUS304 | ||||||
controller | Imported “Excellent and Easy Control” brand temperature instrument | ||||||
Power supply voltage | AC380V±10% 50Hz | ||||||
Note: 1. The test data are all measured when the ambient temperature is 25℃ and the ventilation is good. 2. The above parameters are for reference only and can be customized according to the specific test parameters of users. 3. This technical information is subject to change without prior notice. |
Get Price
ysl@bjyashilin.com 010-68174779Copyright © Beijing Yashilin Test Equipment Co., LTD 备案号:京ICP备08004694号