| Model | Studio Size (D*W*H)mm | Dimension(D*W*H)mm | |
| LRHS-108-RFHY | 450×600×400 | Subject to contractual three-view | |
| LRHS-270-RFHY | 600×900×500 | ||
| LRHS-412-RFHY | 750×1100×500 | ||
| LRHS-663-RFHY | 850×1300×600 | ||
| LRHS-816-RFHY | 850×1600×600 | ||
| LRHS-1080-RFHY | 900×2000×600 | ||
| temperature range | RT+5℃~80℃ | ||||||
| Humidity range | 30%~98% RH | ||||||
| Saturated drum temperature | RT+10℃~70℃ | ||||||
| Temperature uniformity | ≤2℃ | ||||||
| Temperature fluctuation | ±0.5℃ | ||||||
| Salt spray deposition | 1~2ml/80 cm².h(16-hour average) | ||||||
| Compressed air pressure | 2.00±0.01(kg/cm²) | ||||||
| Spraying method | Continuous/periodic selectable | ||||||
| Specimen holder angle | 20±5° | ||||||
| Test Methods | NSS test AASS test CASS test | ||||||
| Case Material | Fiberglass reinforced plastic (FRP) | ||||||
| Lid Material | Fiberglass reinforced plastic (FRP) | ||||||
| Air-saturated drums | High quality premium stainless steel SUS304 | ||||||
| Pressurized Air Hose Material | High quality rubber hose | ||||||
| Other pipelines | Thickened Fluorosilicone Rubber Tubing | ||||||
| Temperature Controller | High-quality “UEC” brand temperature and humidity meter | ||||||
| Dehumidification and cooling | Single or double cascade refrigeration | ||||||
| Compressor | Taikang, France | ||||||
| temperature sensor | PT100 platinum resistance temperature measurement body | ||||||
| heater | Titanium Heating Tube | ||||||
| interrupter | Schneider miniature circuit breakers (to prevent short circuits in control circuits) | ||||||
| standard configuration | Round stick , V-shaped sample shelf , Glass nozzle , Funnel , Metering cylinder , Flexible pipe | ||||||
| security protection | Power leakage protection, Low water level protection, over-load or over-current protection/Dry burning protection | ||||||
| Supply Voltage | AC380V±10% 50Hz | ||||||
| Power | 8.5kW/10.0kW/12.0kW/13.5kW/15.0kW/17.5kW | ||||||
| Temperature: | 5℃~+35℃((Average temperature over 24 hours ≤ 28°C) | ||||||
| Relative Humidity: | ≤85%RH | ||||||
| Note: 1、 the above data are in the use of ambient temperature of 25 ℃ and well ventilated conditions measured 2、Can be customized according to the user’s specific requirements, such as non-standard test chamber 3、This technical information, if there is any change without prior notice |
|||||||