Language
Sizes of Rain Test Chambers | |||||
Model
|
Volume (L)
|
Function
|
Internal Dimension
D*W*H (mm) |
External Dimension
D*W*H (mm) |
Power
|
LRHS-855-PL
|
855
|
IPX3 Test
IPX4 Test |
950*1000*900
|
1350*1400*1350
|
2.5kW
|
LRHS-2551-PL
|
2551
|
1280*1440*1870
|
1520*1830*2100
|
3.0kW
|
|
Specification | |||||
Performance
|
Radius of Swing Pipe | 200mm, 400mm, 600mm and 800mm available (or as per other requirement) | |||
Swing Pipe Speed | 25°~45°/s | ||||
Water Spray Pressure | 50~100kpa | ||||
IPX3 Swing Angle IPX4 Swing Angle |
Spray water from ±60° Spray water for ±170° |
||||
Rotary Table | 1~3r/min | ||||
Water Flow Rate | 0.07L(±5%)/min for each nozzle | ||||
Illumination Lamp | Yes | ||||
Water Required | Purified and softened running water | ||||
Material
|
External Casing | Cold-rolled A3 (Q235) steel plates with plastics painted. | |||
Interior Working Room | Stainless Steel Plates SUS304 with miror surface | ||||
Heat Isolation | Polyurethane foams and fine glass fibres | ||||
Illumination Lamp | Philips® x one | ||||
Casters | 4pcs, with PU covered for protection. Fixable and moveable. | ||||
Viewing Window | Toughened glass with conductive films for heating to defrost | ||||
Door | Manually operated sliding door with unlock button | ||||
Control System
|
Controller | Programmable Touch-screen controller with data logging and download function | |||
Water Storage | Water tank for storing water for recycling use | ||||
Safety Protection | Power leakage protection, over-load or over-current protection/Dry burning protection. | ||||
Voltage | AC220V/380V/440V±10%, 50Hz/60Hz or as per requirement | ||||
Ambient Enviromental for application | 5°C~+30°C ≤ 85%R.H | ||||
Test Standards (not limited to) | IEC 60529 IPX3 and IPX4 |
Get Price
ysl@bjyashilin.com 010-68174779Copyright © Beijing Yashilin Test Equipment Co., LTD 备案号:京ICP备08004694号
Website Map:Sitemap